home_Icon.png:>>>

Sterile Nylon Syringe Filters

Sterile Nylon Syringe Filters

Diameter: 4mm, 13mm, 25mm, 33mm, 50mm
Pore Size: 0.1μm, 0.22μm, 0.45μm, 0.65μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm, 10μm
Inlet: Female Luer lock
Outlet: Male Luer Slip
Housing: PP
Pre-filter: 1μm GF or PP
Maximum Pressure: 5.2bar
Operate temperature: 60℃

Description

Description

Nylon is a kind of hydrophilic membrane to use for aqueous based solvent filtration. Resistant to a range of organic solvents. Suitable for use with high pH samples. Binds proteins features which makes it unsuitable for protein recovery applications.

Advantage

ISO9001, CE double approved, Test Report available, Test Report Available
Using Germany / US imported membrane inside, made in 100,000 class clean room
Ultrasonic welding ensures no contaminant to samples
Medical grade PP housing with wide compatibility with most HPLC sample matrices
Universal Luer fitting ensure compatibly with syringe
Protect any analytical system, extend LC column lifetime,
Luer lock inlet provides strong, leak-tight syringe connection to withstand filtration pressure.
Rugged construction to bear autoclave at 121℃ at 1 bar for 20 minutes/EO/Gamma
100% optical integrity test
Avoid extraneous peaks, false quantitation, sample co-elution, and instrument damage.

Features

Sterile hydrophilic syringe filter
Standard 1μm pre-filter ( Glass fiber or PP ) for optimal performance with particulate-laden analyses
Extremely pure filter with very low extractable or levels
Wide chemical compatibility range
Available diameter: 13mm, 25mm, 33mm
Available pore size: 0.1μm, 0.22μm, 0.45μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm, 10μm
Gamma Sterilization

Applications

Filtration and clarification of small volumes
Sterilization of aqueous and dilute organic solvents
Mixed sample matrix of aqueous or organic dissolved analyze
Biological sample preparation

Chemical Compatibility

Incompatible with
Acids > 1N(Halogenated solvents)
Proteineous samples with high non-specific binding affinities
Acids, Aggressive Halogenated hydrocarbons, protein samples ( Nylon is a high binder)

Technical Data

Filter Media Sterile Nylon
Pore Size, μm 0.1μm, 0.22μm, 0.45μm, 0.65μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm, 10μm
Diameter 4mm 13mm 25mm 33mm 50mm
Housing Medical PP Medical PP Medical PP Medical PP Medical PP
Filtration Area 0.2cm2  1.3cm2 4.9cm2 8.5cm2 19.8cm2
Maximum Pressure 5.2bar 5.2bar 5.2bar 5.2bar 5.2bar
Process Volume 2mL 10mL 100mL 200mL 5000mL
Hold-up Volume < 10μL < 50μL < 100μL < 200μL < 350μL
Inlet Female Luer Lock Female Luer Lock Female Luer Lock Female Luer Lock  Both inlet and outlet is 7-13mm stepped hose barb connection with 6:100 Luer slip
Outlet Male luer slip Male luer slip Male luer slip Male luer slip
Flow Direction Flow should enter from the inlet Both is fine
Maximum Operating Temperature 60℃
Sterilization Gamma Irradiation
Endotoxin ≦0.25 EU/ML

Instruction Drawing

syringe filters analysis chart

Ordering Information

Item Code Pore Size(μm) Diameter(mm) Sterile Pre-filter Quantity/pk
SLNY0410S 0.10 4 Yes No 100pcs
SLNY0422S 0.22 4 Yes No 100pcs
SLNY0445S 0.45 4 Yes No 100pcs
SLNY0465S 0.65 4 Yes No 100pcs
SLNY0480S 0.80 4 Yes No 100pcs
SLNY04100S 1.0 4 Yes No 100pcs
SLNY04300S 3.0 4 Yes No 100pcs
SLNY04500S 5.0 4 Yes No 100pcs
SLNY041000S 10.0 4 Yes No 100pcs
SLNY0410SP 0.10 4 Yes PP 100pcs
SLNY0422SP 0.22 4 Yes PP 100pcs
SLNY0445SP 0.45 4 Yes PP 100pcs
SLNY0465SP 0.65 4 Yes PP 100pcs
SLNY0480SP 0.80 4 Yes PP 100pcs
SLNY04100SP 1.0 4 No PP 100pcs
SLNY04300SP 3.0 4 No PP 100pcs
SLNY04500SP 5.0 4 No PP 100pcs
SLNY041000SP 10.0 4 No PP 100pcs
SLNY0410SG 0.10 4 No GF 100pcs
SLNY0422SG 0.22 4 No GF 100pcs
SLNY0445SG 0.45 4 No GF 100pcs
SLNY0465SG 0.65 4 No GF 100pcs
SLNY0480SG 0.80 4 No GF 100pcs
SLNY0445SG 0.45 4 No GF 100pcs
SLNY0465SG 0.65 4 No GF 100pcs
SLNY0480SG 0.80 4 No GF 100pcs
SLNY04100SG 1.0 4 No GF 100pcs
SLNY04300SG 3.0 4 No GF 100pcs
SLNY04500SG 5.0 4 No GF 100pcs
SLNY041000SG 10.0 4 No GF 100pcs
SLNY1310S 0.10 13 Yes No 100pcs
SLNY1322S 0.22 13 Yes No 100pcs
SLNY1345S 0.45 13 Yes No 100pcs
SLNY1365S 0.65 13 Yes No 100pcs
SLNY1380S 0.80 13 Yes No 100pcs
SLNY13100S 1.0 13 Yes No 100pcs
SLNY13300S 3.0 13 Yes No 100pcs
SLNY13500S 5.0 13 Yes No 100pcs
SLNY131000S 10.0 13 Yes No 100pcs
SLNY1310SP 0.10 13 Yes PP 100pcs
SLNY1322SP 0.22 13 Yes PP 100pcs
SLNY1345SP 0.45 13 Yes PP 100pcs
SLNY1365SP 0.65 13 Yes PP 100pcs
SLNY1380SP 0.80 13 Yes PP 100pcs
SLNY13100SP 1.0 13 No PP 100pcs
SLNY13300SP 3.0 13 No PP 100pcs
SLNY13500SP 5.0 13 No PP 100pcs
SLNY131000SP 10.0 13 No PP 100pcs
SLNY1310SG 0.10 13 No GF 100pcs
SLNY1322SG 0.22 13 No GF 100pcs
SLNY1345SG 0.45 13 No GF 100pcs
SLNY1365SG 0.65 13 No GF 100pcs
SLNY1380SG 0.80 13 No GF 100pcs
SLNY1345SG 0.45 13 No GF 100pcs
SLNY1365SG 0.65 13 No GF 100pcs
SLNY1380SG 0.80 13 No GF 100pcs
SLNY13100SG 1.0 13 No GF 100pcs
SLNY13300SG 3.0 13 No GF 100pcs
SLNY13500SG 5.0 13 No GF 100pcs
SLNY131000SG 10.0 13 No GF 100pcs
SLNY2510S 0.10 25 Yes No 100pcs
SLNY2522S 0.22 25 Yes No 100pcs
SLNY2545S 0.45 25 Yes No 100pcs
SLNY2565S 0.65 25 Yes No 100pcs
SLNY2580S 0.80 25 Yes No 100pcs
SLNY25100S 1.0 25 Yes No 100pcs
SLNY25300S 3.0 25 Yes No 100pcs
SLNY25500S 5.0 25 Yes No 100pcs
SLNY251000S 10.0 25 Yes No 100pcs
SLNY2510SP 0.10 25 Yes PP 100pcs
SLNY2522SP 0.22 25 Yes PP 100pcs
SLNY2545SP 0.45 25 Yes PP 100pcs
SLNY2565SP 0.65 25 Yes PP 100pcs
SLNY2580SP 0.80 25 Yes PP 100pcs
SLNY25100SP 1.0 25 No PP 100pcs
SLNY25300SP 3.0 25 No PP 100pcs
SLNY25500SP 5.0 25 No PP 100pcs
SLNY251000SP 10.0 25 No PP 100pcs
SLNY2510SG 0.10 25 No GF 100pcs
SLNY2522SG 0.22 25 No GF 100pcs
SLNY2545SG 0.45 25 No GF 100pcs
SLNY2565SG 0.65 25 No GF 100pcs
SLNY2580SG 0.80 25 No GF 100pcs
SLNY2545SG 0.45 25 No GF 100pcs
SLNY2565SG 0.65 25 No GF 100pcs
SLNY2580SG 0.80 25 No GF 100pcs
SLNY25100SG 1.0 25 No GF 100pcs
SLNY25300SG 3.0 25 No GF 100pcs
SLNY25500SG 5.0 25 No GF 100pcs
SLNY251000SG 10.0 25 No GF 100pcs
SLNY3310S 0.10 33 Yes No 50pcs
SLNY3322S 0.22 33 Yes No 50pcs
SLNY3345S 0.45 33 Yes No 50pcs
SLNY3365S 0.65 33 Yes No 50pcs
SLNY3380S 0.80 33 Yes No 50pcs
SLNY33100S 1.0 33 Yes No 50pcs
SLNY33300S 3.0 33 Yes No 50pcs
SLNY33500S 5.0 33 Yes No 50pcs
SLNY331000S 10.0 33 Yes No 50pcs
SLNY3310SP 0.10 33 Yes PP 50pcs
SLNY3322SP 0.22 33 Yes PP 50pcs
SLNY3345SP 0.45 33 Yes PP 50pcs
SLNY3365SP 0.65 33 Yes PP 50pcs
SLNY3380SP 0.80 33 Yes PP 50pcs
SLNY33100SP 1.0 33 No PP 50pcs
SLNY33300SP 3.0 33 No PP 50pcs
SLNY33500SP 5.0 33 No PP 50pcs
SLNY331000SP 10.0 33 No PP 50pcs
SLNY3310SG 0.10 33 No GF 50pcs
SLNY3322SG 0.22 33 No GF 50pcs
SLNY3345SG 0.45 33 No GF 50pcs
SLNY3365SG 0.65 33 No GF 50pcs
SLNY3380SG 0.80 33 No GF 50pcs
SLNY3345SG 0.45 33 No GF 50pcs
SLNY3365SG 0.65 33 No GF 50pcs
SLNY3380SG 0.80 33 No GF 50pcs
SLNY33100SG 1.0 33 No GF 50pcs
SLNY33300SG 3.0 33 No GF 50pcs
SLNY33500SG 5.0 33 No GF 50pcs
SLNY331000SG 10.0 33 No GF 50pcs
SLNY5010S 0.10 50 Yes No 25pcs
SLNY5022S 0.22 50 Yes No 25pcs
SLNY5045S 0.45 50 Yes No 25pcs
SLNY5065S 0.65 50 Yes No 25pcs
SLNY5080S 0.80 50 Yes No 25pcs
SLNY50100S 1.0 50 Yes No 25pcs
SLNY50300S 3.0 50 Yes No 25pcs
SLNY50500S 5.0 50 Yes No 25pcs
SLNY501000S 10.0 50 Yes No 25pcs
SLNY5010SP 0.10 50 Yes PP 25pcs
SLNY5022SP 0.22 50 Yes PP 25pcs
SLNY5045SP 0.45 50 Yes PP 25pcs
SLNY5065SP 0.65 50 Yes PP 25pcs
SLNY5080SP 0.80 50 Yes PP 25pcs
SLNY50100SP 1.0 50 No PP 25pcs
SLNY50300SP 3.0 50 No PP 25pcs
SLNY50500SP 5.0 50 No PP 25pcs
SLNY501000SP 10.0 50 No PP 25pcs
SLNY5010SG 0.10 50 No GF 25pcs
SLNY5022SG 0.22 50 No GF 25pcs
SLNY5045SG 0.45 50 No GF 25pcs
SLNY5065SG 0.65 50 No GF 25pcs
SLNY5080SG 0.80 50 No GF 25pcs
SLNY5045SG 0.45 50 No GF 25pcs
SLNY5065SG 0.65 50 No GF 25pcs
SLNY5080SG 0.80 50 No GF 25pcs
SLNY50100SG 1.0 50 No GF 25pcs
SLNY50300SG 3.0 50 No GF 25pcs
SLNY50500SG 5.0 50 No GF 25pcs
SLNY501000SG 10.0 50 No GF 25pcs

More ordering information please click here for review! 
PDFDownload

We have more than thirty lines for the production of micro-porous Membranes, Syringe filters, Sample vials, Septa and caps, along with Filter Paper, Vacuum pumps and manifolds.

ISO
   Contact Form
YOUR NAME
E-MAIL ADDRESS
ENQUIRE
Congratulations, send successfully